Tapk SignaloCentro Facebook bendruomenės dalimi!
Geriausi pasiūlymai Jums!
Termostatas W3230
Programming the thermostat
After turning on the device, the main display will show the current measurement temperature. To set the desired temperature, press the SET button and use the arrows to adjust the value. After setting, confirm the value by pressing the SET button again. To program the device, hold down the SET button until the display shows a mode code, for example P0. Using the SET button, you can switch between modes from P0 to P9. Use the arrows to adjust the values. In the absence of execution of commands on the device, the device automatically exits the setting mode after a period of time. To force quit the setting mode or turn off the device completely, press the "Restart" button.
P0 - Operation mode can be set to heating ("H" - Heating) or cooling ("C" - Cooling).
P1 - Returning the temperature difference - the device returns the difference between the temperature reached and the temperature set during programming.
P2-P3 - Change of limits - if the temperature range from -55 to 120°C is not needed, it can be narrowed down - then only temperatures from this range will be available.
P4- Temperature correction - is needed when there is a discrepancy between the measured and actual temperature value. This function corrects the value by which the temperature reading differs from the actual temperature, e.g. if the measured temperature is 20.5°C and the actual temperature is 20.7°C, then the P4 value should be set as the difference between these values, in this case 0.2°C. Then the displayed temperature will be 20.7°C.
P5 - The delayed start function is intended primarily for cooling the compressor of refrigerators. Typically, a value of 3 to 6 minutes is assumed.
P7 - Once the ON mode is turned on, it is not possible to change the temperature settings and other parameters until it is turned off again.
P8- Restoring factory settings is recommended when the device stops working properly and it is not possible to correct its operation.